Complex Survey Inference Lab
One sample, several standard errors. The naive s/√n pretends the sample were SRS. The design-based SEs use the strata and the PSUs: units in one PSU resemble each other, so the honest SE is larger. Compare them with the true SE from repeated sampling.
SE design 1.339, naive 0.823
Design tree: strata → sampled PSUs
6 of 40 PSUs per stratum, 8 units per PSU; w = (40/a)(M_i/8)
- S1 (w̄ = 39.4)
- PSU 12: n = 8, weighted mean 49.9
- PSU 26: n = 8, weighted mean 51.5
- PSU 10: n = 8, weighted mean 41.9
- PSU 29: n = 8, weighted mean 42.5
- PSU 20: n = 8, weighted mean 42.2
- PSU 32: n = 8, weighted mean 49.8
- S2 (w̄ = 41.1)
- PSU 123: n = 8, weighted mean 47.2
- PSU 118: n = 8, weighted mean 45.0
- PSU 109: n = 8, weighted mean 37.9
- PSU 116: n = 8, weighted mean 43.0
- PSU 125: n = 8, weighted mean 46.1
- PSU 137: n = 8, weighted mean 53.1
- S3 (w̄ = 30.8)
- PSU 230: n = 8, weighted mean 42.4
- PSU 237: n = 8, weighted mean 48.1
- PSU 207: n = 8, weighted mean 51.8
- PSU 204: n = 8, weighted mean 53.9
- PSU 201: n = 8, weighted mean 65.5
- PSU 238: n = 8, weighted mean 49.1
- S4 (w̄ = 34.9)
- PSU 305: n = 8, weighted mean 46.7
- PSU 318: n = 8, weighted mean 60.0
- PSU 333: n = 8, weighted mean 52.4
- PSU 322: n = 8, weighted mean 53.4
- PSU 314: n = 8, weighted mean 52.5
- PSU 321: n = 8, weighted mean 62.8
SE of the mean of y by method
bars: naive s/√n, Taylor linearisation (declared design), the replicate method, and the true SE (SD of the estimate over 300 repeated samples from the population)
95 % CI coverage over 300 samples
naive: 85.3 %
design (t, PSU − H df): 94.7 %
JKn (stratified delete-one-PSU)
Formula
V̂(ȳ_w) = Σ_h n_h/(n_h−1) Σ_i (z_hi − z̄_h)², z_hi = Σ_k w_hik (y_hik − ȳ_w)/Σw